AMD

Face Masks - P2 Respirator Nano-Tech T4 Ear Loop 50pcs

In stock
SKU: ADMP2
Regular price $98.00

Quantity: 1 box (50pcs) Individually Wrapped

Description: Premium Quality Australian Made P2/FFP2 Respirator Masks.

  • As worn by the Australian Olympic Team as AMD are an offical sponsor. 

AMD’s NANO-TECH FFP2/P2 Particulate Respirators (disposable) feature advanced filtering and design details that allow them to be worn comfortably for extended periods of time while maintaining their class-leading functionality over standard melt blown filter respirators. Cutting-edge nanofibre filters are incorporated into a face-contouring design that create an effective barrier against potentially harmful airborne particles and aerosols such as dust, virus, and bacteria. Nanofibre technology ensures excellent breathability and lightness even with the assurance of four protective layers.

Features: Here are 8 reasons you’ll love these P2 respirators:

    • More breathable than almost any other P2 face mask. 
    • First P2 certified respirator masks manufactured in Australia
    • Trusted by medical professionals world-wide
    • Nano-filter filters out 99.66% of airborne particles as tested by VICLAB (BSI) 17.7.20 (compared to approximately 60% for many imported masks)
    • Bacterial Filtration Efficiency (BFE) ≥99.92% AS 4381 Level 3
    • Australia & NZ standard AS/NZS 1716:2012
    • 4 protective layers to help protect you from airborne particulates
    • Cutting-edge nanotechnology, to make them light and breathable

Technology: 

  • Nano-filters, comprised of nanofibres, deliver higher filtration efficiency than standard melt blown filters and are lighter and more breathable.
  • They also maintain their functionality after exposure to moisture while typical filters lose their electrostatic properties once exposed to water.
  • AMD’s nano-filters are water resistant and protective against airborne particles, aerosols, and liquid.

Fit:

  • Innovative three panel design fits naturally around the nose and mouth creating a better seal and aesthetic.
  • Elastic ear loops hold the respirator securely in place.
  • A soft inner layer and moldable padded nose bridge wire provide extra comfort.

Comfort: 

  • ​Nano-filter respirators are lighter than standard respirators and allow enhanced breathability which allow them to be worn for hours. 
  • The three panel design unfolds to shape naturally around the face maximising ventilation around the nose and mouth while still maintaining an effective seal to the environment. Nano-filter respirators are potentially viable options for populations with breathing restrictions such as the elderly and those with heart and lung conditions.
  • Packaging: 

  • Each nano-filter respirator is individually packaged for hygiene and designed to fold flat to facilitate portability and storage.

  • Individual wrapping makes it convenient to carry and distribute without contamination.

  • 50 pieces per box.


DIRECTIONS:

  1. Before putting on the respirator, wash hands for at least 20 seconds with soap and water or rub hands together thoroughly with alcohol-based hand sanitiser.
  2. Take care not to touch the inside layer of the respirator that will be in contact with the nose and mouth when unpacking and while donning.
  3. Check for defects in the face respirator such as tears or broken loops.
  4. Position the label side of the respirator outward and orient the respirator so that the foam nose bridge strip is at the top.
  5. Unfold the respirator while holding onto the edges (again being careful not to touch the area that will be in contact with the nose and mouth). Position the unfolded respirator over the nose and mouth and place one ear loop over each ear.
  6. Mould the nose bridge wire to the bridge of the nose and while pinching the nose bridge in place stretch the bottom of the respirator to over the chin. Press along the edges of the respirator to maximise the seal.
  • Avoid touching the respirator while using it; if touched, clean hands with alcohol-based hand sanitiser or soap and water. 
  • Replace respirator if it becomes obviously contaminated; never reuse single-use respirators.

Removing the respirator:

Wash hands with soap and water or alcohol-based hand sanitiser before removing the respirator. Remove the respirator by unhooking the ear loops, taking care not to touch the front of the respirator which might have become contaminated. Discard immediately in a closed bin and clean hands with alcohol-based hand sanitiser or soap and water.

 Specifications:

Brand AMD
Number per Box 50
Packaging Bulk Case
Features • Australian Made

• Cutting-edge nanofibre filters

• Four-layers with elastic ear loops

• Innovative three panel design improves fit and aesthetic and minimises gaps

• High breathability

• Soft, lightweight, comfortable & odourless

• Individually packed

• Latex free

Filter Included Yes
Face seal/ Nose foam Nose foam
Fluid Resistant (ASTM F1862) No
Flame Resistance (ASTM D2859-96) No
Flammability Rating Class 1
Product Colour White
Product Type Dust and other Particles
Respirator Style Flat Fold
Size Standard
Australia and New Zealand Compliance Standards P2
Standards/Approvals AS/NZS 1716:2012

 

Certification/Class P2
Filter performance ≥ 94%
Test agent NaCl
Flow rate 95 L/min
Total inward leakage (TIL) ≤ 8% leakage
Inhalation resistance ≤ 70 Pa (at 30L/min)≤ 240 Pa (at 95L/min)
Flow rate Varied – see above
Exhalation resistance ≤ 120 Pa
Flow rate 85L/min
Exhalation valve leakage requirement Leak rate ≤ 30mL/min
Force applied -250 Pa
CO2 clearance requirement ≤ 1%


PACKAGING DETAILS:

WEIGHT 0.4 kg
DIMENSIONS 20 × 25 × 12 cm

 

WARNING:

Selection of the most appropriate Respiratory Protective Equipment (RPE) will depend on the particular situation and should be made only by a competent person knowledgeable of the actual working conditions and the limitations of the RPE. Details regarding performance and limitations are specified on the respirator packaging and user instructions. Before using any respirator, the wearer must read and understand the user instructions for the product. Use in accordance with AS/NZS 1716:2012 Standard. Misuse can result in sickness or death. For more information, consult a supervisor or contact an Occupational Hygienist and Safety professional.